IMPROVE YOUR ANNOUNCEMENTS WITH A TOP NOTCH IP PAGING MICROPHONE

Improve Your Announcements with a Top Notch IP Paging Microphone

Improve Your Announcements with a Top Notch IP Paging Microphone

Blog Article

Network PA System for medium to large-scale tasks



Introduction


The XC-9000 system is a completely digital network PA system based on the TCP/IP procedure. By leveraging the TCP/IP protocol, the system guarantees the right and reliable transmission of all data packages. Not only can it utilize existing computer networks, such as LANs or the Net, to send broadcast signals, yet additionally it can likewise be released on a dedicated broadcasting network.


A single-server system can support up to 3000 terminals and enables for web server cascading. There are no limitations on the concurrent program networks, achieving true complete electronic broadcasting.


System Characteristics



Versatile PA System Style


The PA system style is easy, including service management software, network microphones, network amplifiers, network speakers, and various other devices.All tools is attached by means of the TCP/IP intranet procedure, enabling adaptable setup and very easy monitoring of the system, with cost-free control over program material, network tools, and areas with the network.


Ip Pa SystemIp Paging System
Comprehensive Audio Administration


The audio monitoring software application consists of integrated functions for producing broadcast strategies, adaptable zoning, and pre-scheduled broadcasts.It supports 24-hour programs, enabling changing settings during all day


Versatile Sound Source Support


The system supports various types of audio resources for sending alerts like online speech and BGM playback. Sound resources can come from digital music applications, CD/DVD players, microphones, etc. On top of that, the system provides diverse functions of sustaining different broadcasting attributes such as scheduled broadcasting, zoned broadcasting, and emergency broadcasting.


Emergency Alarm System Combination


The system has an emergency alarm function and can be integrated right into a fire alarm system. When the alarm central unit gets the startling signals, the cord will certainly send the signal to tools, which causes the XC-9000, sending out signals to audio speakers


Individuals can choose to pre-programmed settings to trigger full-area or zoned alarms in emergency situations. The alarm system voices can be found in several kinds and can be edited providing to requirements. For example, individuals can change language settings, upload and modify their audio sources according to precise demands, such as intruding alarms, emergency alarm or air help alarm systems, etc





Emergency Alarm System Integration


The system has an emergency alarm function and can be incorporated right into a fire alarm system. When the alarm system main device obtains the startling signals, the cable will certainly transfer the signal to devices, which triggers the XC-9000, sending signals to speakers


Users could choose to predetermined settings to activate full-area or zoned alarm systems in emergencies. The alarm system voices can be found in numerous kinds and might be edited providing to needs. Users can transform language settings, upload and edit their audio sources according to specific needs, such as intruding alarm systems, fire alarms or air help alarms, etc.


Application Control for System Workflow


The system allows mobile app login and usage, permitting individuals to start programs and various other operations to accredited terminals with the web server software, making certain a practical and streamlined experience.


Integrated SIP Compatibility


The system not just allows SIP phones to log in, however likewise can be attached to third-party SIP server or IPPBX, which develops a totally incorporated and suitable communication system via smooth combination into existing systems.


Open up SDK


When large job like wise park happens, the system offers an open SDK integrated into third-party application systems - IP Speaker


System Facilities



Main Features


Scheduled Playback


The system is able to automatically transmit according to the arranged jobs as long as customers upload the audio apply for each amount of time of the day to the web server and produce a playback routine.


Zone Broadcasting


The system can arbitrarily split a couple of network devices right into different areas to play defined audio programs or send news to any designated area. The quantity of each tool can be from another location adjusted.


Real-time Broadcasting


The system can relay and record radio programs or various other exterior audio sources in real-time, and at the very same time broadcast them in sync.


Smoke Alarm Assimilation


The system can be integrated with the smoke alarm system for control. When a fire alarm signal is activated, it immediately triggers the emergency situation program feature and sustains surrounding floor alarm systems. It additionally permits hand-operated emergency broadcasting by clicking a solitary switch.


SIP Phone Assimilation


The system can be incorporated with SIP servers, allowing live speech of voice broadcasting via SIP phones to send out announcements anytime and anywhere.


CCTV Combination


The electronic tools such as IP POE Speakers adopts the international typical ONVIF protocol, which allows their voices to be broadcast via VMS platforms. The terminals can additionally be incorporated with CCTV systems for synchronized broadcast.


Key Products



Sound Management Software XC-9000


B/S style, sustains cross-platform applications.
Covers traditional broadcasting system functions, permitting dividing management.
Unified administration of terminals within the system, viewing job status, and set quantity modification, etc.
Supports structure multi-level Click This Link web server styles, deploying monitoring according to individual geographical regions.
Offers SDK growth packages for second advancement and combination with other system platforms.


Network Paging Console XC-9038N


Power: DC12V/1.5 A.
Show: 4-inch touchscreen, resolution 480 * 480.
Interaction Procedures: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 80dB.
Frequency Reaction: 100Hz~ 16KHz.
Running Temperature: 0~ 45 ℃.
Measurements: 144 * 144 * 34.1 mm.


Network Paging Console XC-9037N


Power Supply: DC12V/1.5 A.
Show: 4-inch touchscreen, resolution 480 * 480.
Communication Protocols: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Frequency Feedback: 100Hz~ 16KHz.
Running Temperature level: 0~ 45 ℃.
Measurements: 144 * 144 * 34.1 mm.


Network Horn Speaker GEN-6391A03


Power Supply: DC24V/2.7 A or POE.
Interaction Method: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Frequency Feedback: 100Hz~ 18KHz.
Intercom: Sustained, Integrated Microphone.
Running Temperature level: -20~ 50 ℃.
Measurements: 283.1 * 224.3 * 269mm.


Network Ceiling Audio Speaker GEN-6211A03


Power Supply: DC 24V/1A or POE.
Communication Protocols: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Regularity Reaction: 100Hz~ 18KHz.
Operating Temperature level: -20 to 50 ° C.
Capacities: φ213 x 165mm.


Network Wall Surface Mount Audio Speaker GEN-6011A03


Power Supply: DC24V/1A or POE.
Communication Protocol: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Regularity Response: 100Hz~ 18KHz.
Operating Temperature: -20~ 50 ℃.
Dimensions: 193x151.5 x292mm.


Network Column Speaker GEN-6191A03




Power Supply: DC24V/1A or POE.
Interaction Method: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 90dB.
Regularity Feedback: 45Hz~ 18KHz.
Running Temperature: -10~ 55 ℃.
Dimensions: 296x140x130mm.


Network Audio Bridge GEN-3101A01


Power Supply: POE.
Interaction Protocol: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 85dB.
Frequency Response: 50Hz~ 20KHz.
Operating Temperature level: -10~ 55 ℃.
Measurements: 126x66x27mm.


Network Digital Amplifier XC-9508P


Power Supply: AC100V~ 240V, 50/60Hz.
Power: 130W, 260W, 360W, 500W.
Interaction Method: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 80dB.
Frequency Response: 60Hz~ 18KHz.
Operating Temperature: -10~ 50 ℃.
Dimensions: 440x300x44mm.


Zone Combining Digital Amplifier NBS-2301


Power Supply : AIR CONDITIONER 220V, 50Hz.
Power : 130W , 260W , 360W , 550W , 700W.
Interaction Protocol : HTTP, TCP/IP, UDP, ARP, ICMP, IGMP.
Signal-to-Noise Ratio :.
Mic Input 01: ≥ 65dB,.
Mic Input 02/03: ≥ 80dB,.
Aux Input 01/02: Recommended Site ≥ 82dB.
Regularity Action :.
Mic Input 01: 80Hz~ 14kHz.
Mic Input 02/03: 60Hz~ 16kHz.
Aux Input 01/02: 60Hz~ 16kHz.
Operating Temperature :.
10 ℃~ +50 ℃ (14 ℉~ 122 ℉)
Measurements : 483x430x88mm.


IP User Interface Device NAC-5003


Power Supply: AC100V~ 240V, 50/60Hz.
Communication Protocol: TCP/IP, UDP.
User interfaces: 1 Ethernet port, 32 alarm inputs, 8 alarm results.
Running Temperature level: -10~ 50 ℃.
Measurements: 483x259x44mm.


Service For School





Versatile Zoning Program:


The fully network terminals can understand flexible zoning choices, permitting for broadcasting notifications to specific terminals or various areas ( devices).


College Bell System:


It gives college bell system at the beginning/ending of the course - IP Speaker. Numerous situations can be designed, including various arranged program tasks according to summer/winter schedule


Smoke Alarm Integration


It supports assimilation with emergency alarm systems, allowing fire alarm signals to be incorporated into the PA system.


Class Sound Amplification


Terminals support daily applications in class scenes. They can be connected to projectors or interactive white boards for audio amplification.


Ip SpeakerIp Speaker

Smart Road Lamp/Security Pole



Support SIP Method:


Integrated SIP procedure for smooth integration with network interaction systems.


VMS Operatings Systems Assimilation:


Integrated ONVIF method for assimilation with VMS systems.


Third-Party Assimilation:


Integrated In HTTP API for integration with 3rd party platforms.


Voice Alarm System Activating:


Built in alarm input interface for causing voice alarm systems with cameras.


Option For Resort



Zone Control by Floor:


The system offers full network settings, separating areas relying upon various floorings and control over each zone independently.


Fire Alarm System Combination:


The system can be integrated with emergency alarm system, allowing combination of fire alarm signals into the broadcasting system.


Scheduled Broadcasting:


It sustains programmable set up broadcasting, allowing flexible setups according to various demands.


Emergency Broadcasting:


It supports emergency broadcasting for the whole area, enabling one-click emergency interaction.


Remedy For Factory



Zone Broadcasting:


It allows broadcasting to any type of area, guaranteeing no disturbance in between various locations.


Alarm system Triggering:


Terminals have numerous kinds of user interfaces, making it possible for to cause alarm systems when linked with video cameras.


All Network Instruments:


Implementation of fully network gadgets significantly minimizes the trouble of operating such as inspecting gadgets on hazardous sites, and hence protecting people and residential property.


The release of all network gadgets substantially decreases the difficulty of operation and maintenance administration


Integrated SIP Phones:


The system can be integrated with SIP phone and broadcast alerts utilizing SIP phones at any moment and anywhere. Two-way audio talkback between SIP phones and IP POE Audio speakers makes it simple for checking gadgets being in go to this site office or various other offices.


The XC-9000 system is a totally electronic network PA system based on the TCP/IP procedure. By leveraging the TCP/IP procedure, the system makes sure the right and reliable transmission of all data packages. The system supports numerous forms of audio sources for sending out alerts like live speech and BGM playback. In addition, the system gives diverse functions of sustaining various broadcasting attributes such as scheduled broadcasting, zoned broadcasting, and emergency situation broadcasting.


The system can be incorporated with the fire alarm system for control.

Report this page